Poly Lam
Products, Corp.
Your Controlled Atmosphere Packaging Experts
|
Call us toll free at 1-800-836-9648
|
Home
/
Desiccant /
Oxygen Absorber /
Humidity Indicators /
Data Loggers /
Spill Control /
VCI Corrosion Control
iLog Data Recorders
|
 |
|
 |
|
 |
 |
|
 |
 |
 |
 |
 |
iLog Internal Temperature Loggers
|
|
Product Code: ilog EI-IN-D-32-L |
|
|
|
|
|
|
 |
1
Internal Temperature sensor |
|
 |
Internal sensor range from -40°C to
+70°C |
|
 |
Accuracy: ± 0.35°C from -40°C to 0°C, ±
0.25°C from 0°C to +70°C |
|
 |
Resolution 0.1°C |
 |
Memory 32,000
samples |
|
 |
Active & Alarm
LED's |
 |
LCD Display |
|
 |
IP Rating 67 |
 |
Size: Diameter 76
mm, Height 18mm |
|
 |
Software: ESCORT
Console |
|
|
|
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
|
|
|
 |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
iLog External Temperature Loggers
|
|
Product Code: ilog EI-1E-D-32-L |
|
|
|
|
|
|
 |
1 Internal and
1 External Temperature sensors |
|
 |
Internal
sensor range from -40°C to +70°C |
|
 |
External
sensor range from -40°C to +70°C |
|
 |
Accuracy: ±
0.35°C from -40°C to 0°C, ± 0.25°C from 0°C to
+70°C |
|
 |
Resolution 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm LED's |
 |
LCD Display |
|
 |
Size: Diameter 76 mm,
Height 18mm |
 |
Software: ESCORT Console |
|
 |
IP Rating 65
(when external sensor is connected) |
|
 |
Probe size 80 x 4.5 mm,
Cable length 1m |
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
|
|
 |
|
 |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
iLog External Temperature Loggers
|
|
Product Code: ilog EI-1E-DC-32-L |
|
|
|
|
|
|
|
|
|
|
 |
1
Internal and 1 External Temperature sensor |
|
 |
Internal sensor range from -40°C to +70°C |
|
 |
External sensor range from -20°C to +100°C |
|
 |
Internal
sensor accuracy: ± 0.35°C from -40°C to 0°C, ±
0.25°C from 0°C to +70°C |
|
 |
External sensor accuracy: ±
0.30°C from -20°C to 0°C, ± 0.25°C from 0°C to
+70°C,
± 0.30°C from +70°C to +100°C |
|
 |
Internal &
External Sensors resolution: 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm
LED's |
 |
LCD Display |
 |
Diameter 76 mm,
Height 18mm |
|
 |
IP
Rating 65 (when external sensor is connected) |
|
 |
Probe Size 80 x 4.5 mm, Cable length 1m |
 |
Software: ESCORT
Console |
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
iLog External Temperature Loggers
|
|
Product Code: ilog EI-1E-DN-32-L |
|
|
|
|
|
|
|
|
|
|
 |
1
Internal and 1 External Temperature sensors |
|
 |
Internal sensor range from -40°C to +70°C |
|
 |
External sensor range from -100°C to +40°C |
|
 |
Internal
sensor accuracy: ± 0.35°C from -40°C to 0°C, ±
0.25°C from 0°C to +70°C |
|
 |
External sensor accuracy: ±
1.0°C from -100°C to -80°C, ± 0.5°C from -80°C
to -50°C, ± 0.3°C from -50°C to +40°C |
|
 |
Internal &
External Sensors resolution 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm
LED's |
 |
LCD Display |
 |
Diameter 76 mm,
Height 18mm |
|
 |
IP
Rating 65 (when external sensor is connected)
|
|
 |
Probe Size 80 x 4.5 mm, Cable length 1m |
 |
Software: ESCORT
Console |
|
|

|
|
|
|
|
|
|
|
|
|
 |
|
 |
|
|
 |
|
 |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
iLog External Temperature Loggers
|
|
Product Code: ilog EI-1E-DZ-32-L |
|
|
|
|
|
|
|
|
|
|
 |
1
Internal and 1 External Temperature sensors |
|
 |
Internal sensor range from -40°C to +70°C |
|
 |
External sensor range from 0°C to +150°C |
|
 |
Internal
sensor accuracy: ± 0.35°C from -40°C to 0°C, ±
0.25°C from 0°C to +70°C |
|
 |
External sensor accuracy: ±
0.30°C from 0°C to +90°C, ± 0.45°C from +90°C to
+120°C, ± 0.75°C from +120°C to +150°C |
|
 |
Internal &
External sensors resolution 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm
LED's |
 |
LCD Display |
 |
Diameter 76 mm,
Height 18mm |
|
 |
IP
Rating 65 (when external sensor is connected) |
|
 |
Probe Size 80 x 4.5 mm, Cable length 1m |
 |
Software: ESCORT
Console |
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
|
|
 |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
iLog with 2 External Temperature Sensors
|
|
Product Code: ilog EI-2E-D-32-L |
|
|
|
|
|
|
|
|
|
 |
2 External
Temperature sensors (no internal) |
|
 |
External
sensors range from -40°C to +70°C |
|
 |
External sensors accuracy
: |
± 0.35°C from
-40°C to 0°C, |
|
|
|
± 0.25°C from
0°C to +70°C |
|
 |
External
sensors Resolution 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm
LED's |
 |
LCD Display |
|
 |
IP Rating 65
(when external sensors are connected) |
|
 |
Size: Diameter
76 mm, Height 18mm |
|
|
|
 |
Probe Size 80
x 4.5 mm, Cable length 1m |
 |
Software: ESCORT Console |
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
 |
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
iLog with 2 External Temperature Sensors
|
|
Product Code: ilog EI-2E-C-32-L |
|
|
|
|
|
|
 |
2 External
Temperature sensors (no internal) |
|
 |
External
sensors range from -20°C to +100°C |
|
 |
External sensors accuracy: ±
0.30°C from -20°C to 0°C, ± 0.25°C from 0°C to
+70°C, ± 0.30°C from +70°C to +100°C |
|
 |
External Sensors
Resolution 0.1°C |
 |
Memory 32,000 samples |
|
 |
Active & Alarm LED's |
 |
LCD Display |
|
 |
IP Rating 65
(when external sensors are connected) |
|
 |
Size: Diameter 76 mm,
Height 18mm |
|
|
|
 |
Probe Size 80 x 4.5 mm,
Cable length 1m |
 |
Software: ESCORT Console |
|
|

|
|
|
|
|
|
|
|
|
|
 |
|
 |
|
|
 |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
iLog Humidity Loggers
|
|
Product Code: EI-HS-D-32-L |
|
|
|
|
|
|
 |
1 Internal
Temperature and 1 Humidity sensors |
|
 |
Internal
sensor range from -40°C to +70°C |
|
 |
Internal
sensor accuracy: ± 0.35°C from -40°C to 0°C, ±
0.25°C from 0°C to +70°C |
|
 |
Internal sensor resolution
0.1°C |
 |
Active & Alarm LED's |
|
 |
Humidity sensor range from
0 to 100% RH |
|
|
|
 |
Humidity Sensor Resolution
0.1% RH |
 |
Humidity sensor accuracy ±
3% |
|
 |
Memory 32,000 samples |
 |
LCD Display |
|
 |
IP Rating 65 (with dust
filter) |
 |
Diameter 76 mm, Height
18mm |
|
 |
Software: ESCORT Console |
|
|
|
|
|
|
|
|

|
|
|
|
|
|
 |
|
 |
|
|
|
|
|